 Monitoring Relays AC Current Transformer Types A 82-10, A 82-20
* 5 types of input: 0 - 25 AAC 0 - 50 AAC 0 - 100 AAC 0 - 250 AAC 0 - 500 AAC * Output: A 82-10: 0 - 20 mADC (source) A 82-20: 4 - 20 mADC (sink) * Easy interface to PLC or setpoint relays
Product Description
AC current metering transformer for 25, 50, 100, 250 or 500 AAC. Output current from the transformer is 0-20 mADC or 4-20 mADC in accordance with IEC 60381-1. Can be used with relays DIB01, PIB01, DIC01, PIC01 or S183 or directly connected to a PLC. Power supply ON is indicated by a green LED on the side of the housing.
Ordering Key
Type Output Input current
A 82-10 50
Type Selection
Input current 25 AAC 50 AAC 100 AAC 250 AAC 500 AAC 25 AAC 50 AAC 100 AAC 250 AAC 500 AAC Output current 0 - 20 mA 0 - 20 mA 0 - 20 mA 0 - 20 mA 0 - 20 mA 4 - 20 mA 4 - 20 mA 4 - 20 mA 4 - 20 mA 4 - 20 mA Type no. A 82-10 25 A 82-10 50 A 82-10 100 A 82-10 250 A 82-10 500 A 82-20 25 A 82-20 50 A 82-20 100 A 82-20 250 A 82-20 500
Input Specifications
A 82-10/20 25 Current range 0 - 25 AAC Max. current (continuously) 30 AAC Max. overload current (t = 30 s) 250 AAC Rated insulation voltage Input - output 1000 VAC rms Overvoltage category IV (IEC 60664) Dielectric strength Dielectric voltage 6 kVAC rms Rated impulse withstand volt. 12 kV (1.2/50 s) A 82-10/20 50 0 - 50 AAC 60 AAC 300 AAC 1000 VAC rms IV (IEC 60664) 6 kVAC rms 12 kV (1.2/50 s) A 82-10/20 100 0 - 100 AAC 120 AAC 700 AAC 1000 VAC rms IV (IEC 60664) 6 kVAC rms 12 kV (1.2/50 s) A 82-10/20 250 0 - 250 AAC 300 AAC 1500 AAC 1000 VAC rms IV (IEC 60664) 6 kVAC rms 12 kV (1.2/50 s) A 82-10/20 500 0 - 500 AAC 600 AAC 3000 AAC 1000 VAC rms IV (IEC 60664) 6 kVAC rms 12 kV (1.2/50 s)
Specifications are subject to change without notice (25.01.06)
1
A 82-10, A 82-20
Output Specifications
Rated insulation voltage (cable) Output current 10: 20: Power supply (loop voltage) Tolerance of output current @ 50 Hz A 82-10 A 82-20 Temperature variation Frequency range Frequency variation Maximum output current 250 VACrms 0 - 20 mADC 4 - 20 mADC 10 - 40 VDC 2% 0.08 mA 2% 400 ppm/C 40 Hz -1 kHz 10 ppm/Hz 35 mADC
General Specifications
Power ON delay Reaction time <1s < 100 ms worst case reaction time may be up to 5 x LED, green IP 20 3 (IEC 60664) -20 to 50C (-4 to +122 F) 95 x 67.5 x 20 mm ABS 300 g 270 g 2 m, 3 x 0.25 mm2 2 m, 2 x 0.25 mm2 UL Yes Electromagnetic Compatibility Acc. to EN 61000-6-1 (tolerance of output current: 2%) Acc. to EN 61000-6-2 (tolerance of output current: 5%) Acc. to EN 61000-6-3
Indication for Power supply ON Environment Degree of protection Pollution degree Operating temperature Housing Dimensions Material Weight A 82-10 A 82-20 Connection cable A 82-10 A 82-20 Approval CE marking EMC Immunity
Emission
Mode of Operation
A 82-10, A 82-20 are current metering transformers with standard source/sink output 0 - 20 mA/4 - 20 mA. This makes it very useful as an AC current interface to a PLC with mADC input. Used with relays DIB01, PIB01, DIC01, PIC01 or S183 one or more setpoints can monitor the current and signal alarm. S 183 also provides the DC voltage supply for the A 82-10, A 82-20. The metered conductor is drawn through the central hole of the current metering transformer. It is possible to meter currents below the nominal range by drawing the conductor through the hole several times. If the conductor is drawn through the central hole e.g. 5 times, the transformer will register 50 A when the current in the conductor is 10 A. A 82-10 has factory-set gain (span) adjustment, whereas A 82-20 has zero as well as gain (span) adjustment, both factory-set. Note: Do not change the set values.
Wiring Diagrams
A 82-10 ... (source)
I Red Yellow R load Power + supply Black Loop + voltage Grey Black R load
A 82-20 ... (sink)
I
2
Specifications are subject to change without notice (25.01.06)
A 82-10, A 82-20
Input/Output Curve
Output (mADC)
Resistance/Voltage Curve
Max. R load ()
20 16 12 8 4
A 0 -2 82
A
0 -1 82
50
100
Input (% of range)
(V)
Power supply (loop voltage)
Max. load resistance versus Power supply (loop voltage)
Dimensions
Specifications are subject to change without notice (25.01.06)
3


▲Up To Search▲   

 
Price & Availability of A82-20500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X